Hydraulic oil is happiest between roughly 40 and 55 degrees C, with many OEMs targeting 49–60 degrees C at the tank. Above 60 degrees C seal life falls away quickly; above 70 degrees C oxidation accelerates, viscosity drops below pump minimums, and varnish starts to form. Varnish is the expensive failure: it clogs valves and filters quietly.
Why plate-fin, not tube-and-fin:
Heat density in a tight package. Modern off-highway machines put a Tier 4 Final engine, aftertreatment, charge air cooler, radiator and hydraulic cooler into a hood envelope that did not grow. Plate-fin cores carry far more area per cubic metre, which is the only way to fit the duty.
Air-side fouling is the design condition, not the exception. Dust, chaff and mud are normal. Straight or wide-fin geometries with generous fin spacing foul slower and clean easier than dense serpentine cores.
Shock and vibration. Brazed aluminium plate-fin blocks have no tubes to fatigue at a joint, and the fin carries load. That matters on a machine that cycles twenty thousand times a day.
Cold starts. A US fleet spans Arizona summer and Minnesota winter. Oil at minus 30 degrees C is thick, and the cooler has to survive pressure spikes at startup without cracking a header.
Fluid compatibility is where US projects get specific. Mineral oil is easy. Biodegradable and bio-based fluids, and water-glycol where fire risk is regulated, change the wetted-material and seal story — always confirm with the fluid supplier rather than the datasheet.
One more US pattern worth noting: buyers here replace coolers as service parts long after the machine leaves warranty, so availability and dimensional interchangeability matter as much as thermal margin. A cooler that fits but cannot be sourced in five years is a warranty problem.
Three numbers to put on the RFQ: oil flow at rated engine speed, allowable oil-side pressure drop, and ambient design temperature. Everything else follows.
What ambient and duty cycle are you actually sizing to — 40 degrees C continuous, or a desert afternoon?
#Hydraulics #OilCooler #PlateFin #OffHighway #HeatExchanger
Whatsapp:+86 15603820837
[email protected]
[email protected]
1
3
69
Introducing our flat dry cooler equipped with EC910 fans, specially engineered for immersion cooling. It covers a cooling capacity range from 50kW to 2MW, ideal for immersion cooling systems of data centers and crypto mining (Bitcoin) facilities, serving markets across Europe, the Middle East, Russia and the United States.
Fitted with high-efficiency EC910 electronically commutated axial fans, the unit supports stepless variable speed. It automatically adjusts airflow based on coolant temperature and real-time heat load, cutting fan power consumption and noise, maximizing free cooling hours and lowering PUE. Featuring a compact flat layout, the coil adopts anti-corrosion coated fins with stable working pressure. Compatible with glycol, dielectric cooling fluids and other media, it consumes zero evaporative water, avoids legionella risks and requires minimal maintenance.
Rigorously tested under extreme temperature and salt-fog conditions, it adapts to diverse climates: high heat and sand in the Middle East, freezing winters in Russia, and humid coastal environments in Europe & America. The modular design supports standalone operation or parallel connection for large cooling clusters.
We offer matched electric control, temperature monitoring and remote communication ports, compliant with CE, UL and other regional certifications. For fast-growing global computing infrastructure, this dry cooler delivers reliable, water-saving and energy-efficient heat rejection. OEMs, system integrators and mining operators are welcome for custom design and bulk orders.
#DryCooler #ImmersionCooling #DataCenterCooling #LiquidCooling
Whatsapp:+86 15603820837
[email protected]
[email protected]
1
68
Plate-Fin Heat Exchanger for Refrigerated Air Dryer | 70m³/min, Indonesia Market
This three-in-one plate-fin heat exchanger for refrigerated air dryers is specially developed for the hot and humid tropical working conditions in Indonesia. With a rated processing flow of 70m³/min, it integrates heat recovery, evaporation and gas-liquid separation channels. As the core heat exchange component for large compressed air post-treatment systems, it is widely matched with air supply equipment for mines, factories and construction machinery.
✅ Key Specifications: Rated air flow 70m³/min; design working pressure 0.7~1.0 MPa; inlet air temperature ≤45℃; stable pressure dew point 2~8℃; total pressure drop ≤0.02 MPa. Adopting vacuum-brazed aluminum plate-fin core, it resists heat, humidity and condensate corrosion, perfectly adapting to Indonesia’s year-round high temperature, heavy rainfall and salty moist air.
The compact integrated channel design greatly reduces footprint compared with traditional shell-and-tube exchangers while delivering high heat transfer efficiency. It uses waste heat from inlet air for pre-cooling to cut refrigeration load and help end users save power and operating costs. Every core is tested for air tightness and pressure resistance to eliminate internal cross-leakage risks and ensure stable continuous operation.
Compatible with eco-friendly refrigerants R134a and R407C. Custom ports and mounting dimensions are available per OEM drawings. We serve local Indonesian air compressor and post-processing equipment OEMs. Thermal calculation, prototype testing and factory inspection reports can be provided to meet local industrial project acceptance standards with reliable mass delivery. Manufacturers and distributors in Indonesia are welcome for technical communication and bulk orders.
#PlateFinHeatExchanger #RefrigeratedAirDryer #CompressedAir #HeatTransfer #IndonesiaOEM
Whatsapp:+86 15603820837
[email protected]
[email protected]
70
Plate-Fin Heat Exchanger Core Production & Assembly Line
The plate-fin core serves as the core component of compact heat exchange equipment. Its stacking precision, cleanliness and brazing consistency directly determine heat transfer efficiency, pressure resistance and service life of heat exchangers. We have built an integrated automated core production and assembly line covering fin forming, ultrasonic degreasing cleaning, precision layered stacking, fixture setting, vacuum brazing, reshaping and full inspection, delivering process control and traceability.
Equipped with positioning jigs and vision-aided verification systems, the line strictly manages the arrangement of separators, fins, sealing strips and guide vanes. It accurately controls channel spacing to eliminate assembly defects such as misalignment, offset and fin collapse. Multi-stage ultrasonic cleaning before brazing thoroughly removes surface oil, aluminum powder and oxide films to ensure uniform filler metal wetting and stable metallurgical bonding. Stacked cores are pre-pressed and shaped by fixtures before vacuum brazing. Heating curve, vacuum level and holding period are closely monitored to reduce brazing deformation and micro-leakage risks.
Every finished core undergoes visual inspection, dimensional recheck, air tightness test and pressure test. Sampling penetrant inspection is carried out on critical welds to meet demanding working conditions in construction machinery, air compressors, energy storage and oil & gas industries. The line supports flexible production of aluminum, stainless steel and titanium alloy cores. Flow channel structures, fin specifications and pressure ratings can be customized according to customers’ thermal designs with high batch consistency. Backed by standardized production and process control, we supply reliable plate-fin cores for global OEM clients. Technical discussions and factory audits are welcome.
#HeatExchanger #PlateFinCore #VacuumBrazing #HeatTransfer #OEMManufacturing
Whatsapp:+86 15603820837
[email protected]
[email protected]
88
We present our hydraulic oil cooler with solenoid directional valve controlled motor for the Polish market, featuring a rated heat exchange capacity of 48kW, engineered for reliable temperature control of industrial hydraulic systems. It is an ideal match for local OEMs, hydraulic system integrators and construction machinery applications across Poland.
This cooler adopts a hydraulic motor-driven fan design integrated with a solenoid directional valve. Electric control enables automatic start, stop and direction switching of the motor for intelligent temperature regulation. The cooling system activates when oil temperature rises above the set threshold and shuts down under low-temperature conditions to save energy and prevent overcooling, delivering fast response under demanding working conditions. Equipped with a high-efficiency plate-fin heat exchanger core, it provides outstanding thermal performance with low pressure drop, strong shock resistance and good compatibility with hydraulic oil, suitable for Poland’s variable climate and continuous workshop operation.
Key specifications: Heat exchange power 48kW, hydraulic drive motor, solenoid directional valve control module, max working pressure 16 bar, compatible with standard hydraulic oils, 24V electric control, EU-standard mounting connections for straightforward integration and replacement on existing hydraulic stations.
The compact unit comes with a protective housing for easy maintenance and low failure rate. It stabilizes hydraulic oil temperature, protects seals, pumps and motors, slows oil degradation and extends the service life of the whole hydraulic system. Customization on ports and temperature control logic is available. We support certification coordination, stable lead time and sample testing for Polish partners. Hydraulic integrators and equipment manufacturers are welcome to contact us for drawings and technical support.
Whatsapp:+86 15603820837
[email protected]
[email protected]
1
60
Plate Fin Heat Exchanger | Professional Thermal Management Manufacturer
We are a specialized manufacturer focusing on the R&D and production of plate fin heat exchangers. Backed by an experienced management team and in-house technical research & development center, we have years of expertise in heat transfer technology. We keep upgrading our brazing processes, flow channel simulation and performance testing systems to develop high-efficiency customized heat transfer solutions for customer-specific working conditions.
Supported by a mature quality control system and standardized production lines, our plate fin heat exchangers feature high heat transfer efficiency, compact structure, stable pressure resistance and excellent vibration resistance, suitable for multi-fluid heat exchange requirements. Our products serve a wide range of sectors including hydraulic cooling for construction machinery, post-processing of air compressors, energy storage liquid cooling, data center thermal management, rail transit and cryogenic air separation. They are capable of harsh operating conditions across different regions, with support for both standardized bulk supply and project-based customization.
Our team provides full-cycle support from thermal calculation and structural design at the early stage, to sample testing, mass production and after-sales technical service. Every process is strictly controlled to guarantee product consistency and reliability. We continuously benchmark premium international heat transfer products, optimizing fin structures and brazing craftsmanship to help OEM clients control temperature rise, cut energy consumption and extend equipment service life.
For global OEMs and system integrators, we deliver stable supply and rapid response, delivering trusted heat transfer solutions to meet thermal management demands from diverse industries.
Whatsapp:+86 15603820837
[email protected]
[email protected]
1
84
Air Compressor Aftercooler Integrated System
This integrated air compressor aftercooler system is equipped with a precision air filter and air source two-unit combination, with a rated processing flow of **375 CFM (10.6 m³/min)**. It is specially matched for mobile screw air compressors to complete cooling, water removal, filtration and pressure regulation of high-temperature compressed air in one stop, widely used in mining, sandblasting, infrastructure construction and other working conditions.
Key parameters: flow rate 375 CFM, rated working pressure 10 bar, inlet air temperature ≤180°C, outlet air temperature after cooling close to ambient temperature +10°C. The multi-stage filter element of the air filter intercepts dust, liquid water droplets and oil mist with a filtration accuracy of 1 μm and low pressure drop for stable air supply. The supporting two-unit combination integrates filter and pressure reducing valve with adjustable pressure, high voltage stabilization accuracy and auto drain structure to cut manual maintenance.
Adopting plate-fin heat exchange core, the unit features high heat transfer efficiency, compact structure and vibration resistance for dusty and bumpy job sites. With modular design, the aftercooler, air filter and two-unit combination come with pre-assembled pipelines for easy installation. Universal interfaces allow direct replacement of cooling assemblies from mainstream brands.
Stable temperature control greatly reduces moisture content in compressed air, protects downstream pneumatic tools and sandblasting equipment, prevents pipeline corrosion and valve jamming, extends service life and cuts downtime & maintenance costs. It adopts air cooling without external water supply, ideal for field sites with no water access.
Custom heat exchange cores and different pressure versions are available. We serve air compressor OEMs and distributors worldwide with drawings, samples and bulk delivery. Welcome to contact us for cooperation.
#hashtags #AirCompressor #Aftercooler #PlateFinHeatExchanger #PneumaticComponents
Whatsapp:+86 15603820837
[email protected]
[email protected]
90
FLJ Series | Integrated Hydraulic Oil Cooling System for Concrete Mixers, Globally Compatible
The FLJ series is an all-in-one hydraulic oil cooling assembly specially developed for concrete mixer truck hydraulic systems, serving OEM and replacement markets worldwide. With unified specifications and standardized mounting dimensions, it greatly simplifies selection, assembly and after-sales inventory management for manufacturers.
Three hydraulic tank capacities are available: **18L / 26L / 32L**. The complete unit integrates a thermostat, DC cooling fan and switch box. Automatic temperature control precisely stabilizes hydraulic oil temperature, preventing oil degradation and abnormal wear of hydraulic pumps and reducers caused by overheating, to ensure reliable continuous operation of mixers.
The integrated design cuts separate component purchases and reduces the risk of pipeline leakage. Thanks to universal mounting connections, retrofitting on existing models requires no frame modification, suitable for original matching and refitting of various mixer brands. The DC fan features excellent vibration resistance, built to withstand harsh site conditions including bumpy roads, high temperatures and heavy dust. Its stable performance has been proven on construction sites across Southeast Asia, the Middle East, Latin America and beyond.
Standardized mass production guarantees consistent lead times. Drawings and performance reports are supplied to support bulk OEM orders and stock preparation for overseas distributors. Balancing versatility and durability, it helps customers reduce SKUs and shorten assembly time. Global construction machinery OEMs and spare parts distributors are welcome to inquire about samples and discuss long-term cooperation.
Whatsapp:+86 15603820837
[email protected]
[email protected]
65
Combined Heat Exchanger for Refrigerated Air Dryers | For Vietnam Factories, Stable Air Supply at 13m³/min
Designed for air compressor supporting, injection molding, sheet metal, packaging and other industrial applications in Vietnam, this 2-in-1 integrated heat exchanger combines pre-cooling and evaporating heat exchange in one unit. It is optimized for hot and humid working conditions to tackle common pain points in Vietnam, such as unstable water drainage, excessive pressure drop and corrosion risks of refrigerated dryers.
Key specifications: Rated air flow **13Nm³/min**, working pressure range 0.7–1.0 MPa, standard pressure dew point 2–10℃. Adopting plate-fin structure, it delivers high heat transfer efficiency and low pressure drop to cut extra power consumption of air compressors. The anti-corrosion treated aluminum housing withstands humid rainy seasons and salty air, perfectly fitting year-round high inlet temperature conditions in industrial zones of Ho Chi Minh, Binh Duong, Bac Ninh and other areas.
Compared with separate heat exchange assemblies, the compact integrated design reduces piping requirements, saves 30% installation space and lowers leakage risks and on-site assembly costs, ideal for mass matching by refrigerated dryer OEMs. It supports air-cooled units. Custom flange sizes and upgraded anti-corrosion options are available. Complete documentation is provided for local inspection and technical communication.
With mature foreign trade supply chain and stable lead time, we supply drawings and performance test reports for local dryer manufacturers and their export business. It maintains stable compressed air quality to protect pneumatic valves, cylinders and precision machinery from rust damage. OEMs and distributors in Vietnam are welcome for sample testing and long-term partnership negotiation.
Whatsapp:+86 15603820837
[email protected]
[email protected]
81
Hot Aussie jobsites demand rock-solid cooling for your 220kW dozer, and our 4-in-1 composite heat exchanger is built exactly for that harsh Australian environment.
This integrated unit combines **water radiator, hydraulic oil cooler, charge air cooler and fuel cooler** in one compact assembly, tailored for 220kW bulldozers working across mines, quarries, earthmoving and rural land clearing. Instead of four separate coolers taking up valuable engine bay space, our plate-fin composite design consolidates all four cooling circuits, cutting installation complexity, reducing leak points and simplifying maintenance for field service teams.
Australia’s high ambient heat, dust, and continuous heavy-load operation push cooling systems to the limit. Consistent engine water temperature protects the main engine from overheating. The hydraulic oil cooler stabilizes oil viscosity to preserve pushing power and extend pump and motor service life. The charge air cooler delivers denser intake air, boosting combustion efficiency and lowering exhaust temperatures for steady 220kW power output. The dedicated fuel cooler controls fuel temperature, preventing vapor lock and maintaining stable fuel supply on long shifts.
Vacuum-brazed aluminium core brings outstanding thermal transfer efficiency, anti-corrosion performance and shock resistance. Optimized fin layout resists dust clogging, a huge advantage on dry, dusty Aussie sites. Direct bolt-on fit reduces downtime during radiator replacement.
For Australian dozer owners, fleet managers and repair workshops, reliable cooling means fewer unexpected breakdowns, longer service intervals and better return on machine investment. Whether you operate in WA, QLD or NSW remote worksites, this 4-way composite cooler keeps your 220kW dozer pushing hard all day long.
Message us today for drawings, performance data and quotation.
#BulldozerParts #ConstructionMachinery #HeatExchanger #MiningEquipment #AustraliaEarthmoving
Whatsapp:+86 15603820837
[email protected]
[email protected]
123
For construction machinery OEM partners in Istanbul, we present our high-performance plate-fin hydraulic oil cooler with 68kW cooling capacity, tailored for heavy-duty hydraulic circuits of excavators, loaders and material-handling equipment.
Built with fully welded aluminum plate-fin core, this cooler delivers stable heat dissipation under Turkey’s high ambient temperature, dust and vibration site conditions, protecting hydraulic pumps, main valves and motors from overheating, oil aging and unexpected downtime.
📋 Key Technical Parameters
✅ Cooling capacity: 68kW (at 40℃ ambient, oil inlet 70℃)
✅ Max working pressure: 2.0 MPa, test pressure: 3.0 MPa
✅ Recommended hydraulic flow: 240 L/min
✅ Core material: 3003 aluminum alloy, anti-corrosion brazed structure
✅ Fan option: DC24V / hydraulic motor driven, low noise
✅ Oil port: Custom flange or thread connection per OEM drawing
✅ Pressure drop: ≤0.12 MPa at rated flow
✅ Mounting: Custom bracket design for direct chassis integration
We fully support Istanbul-based machinery manufacturers on co-development, thermal simulation and sample validation. Compact layout, low flow resistance and robust anti-vibration structure simplify chassis arrangement, perfectly matching local construction, quarry and infrastructure projects across Türkiye.
Our engineering team provides one-stop service: thermal matching, prototype trial, CSC certification and local after-sales coordination. We can adjust size, port position and fan configuration according to your host machine design, helping you shorten R&D cycle and improve whole-machine reliability.
For Turkish OEMs pursuing stable hydraulic thermal management, this 68kW hydraulic cooler is a cost-effective, long-life solution. Welcome Istanbul machinery manufacturers to contact us for technical discussion, quotation and on-site test support.
#HydraulicCooler #ConstructionMachinery #HeatExchanger #TurkeyOEM #IstanbulMachinery
Whatsapp:+86 15603820837
[email protected]
[email protected]
39
Our combined plate-fin heat exchanger with hydraulic motor drive is built to withstand Australia’s tough off-highway conditions, widely fitted on excavators, wheel loaders and mining support machinery across WA, QLD and NSW. This integrated composite core combines hydraulic oil cooling and charge air cooling in one compact brazed aluminium assembly, removing the need for separate coolers and simplifying chassis layout.
**Key technical parameters**: Cooling capacity up to 75 kW, oil-side working pressure 20 bar, test pressure 35 bar, max oil inlet temperature 120°C, rated oil flow 60–240 L/min. The matched hydraulic fan motor displacement is 12 cm³/r, supporting variable fan speed linked to oil temperature. It works reliably under ambient temperature from -20°C to +45°C, suitable for Australia’s summer heat, dust and frequent heavy cyclic loads.
Vacuum brazed 3003 aluminium alloy core delivers high structural rigidity and anti-corrosion performance. The fin spacing is optimised for dusty quarry and construction sites, reducing clogging and cutting downtime. With built-in low pressure drop design, it will not add extra load to the main hydraulic circuit. The hydraulic motor drive eliminates dependence on machine electric systems, a major advantage for heavy-duty mobile equipment.
Many Australian OEMs and cooler rebuilders now select this composite exchanger for new machine assembly and aftermarket replacement. We support customised core size, port connection (BSPP / SAE) and anti-dust coating options, with fast lead time and local technical support.
Overheating is one of the top causes of hydraulic motor failure and shortened component life. This all-in-one thermal package stabilises oil temperature within 50–60°C under peak load, protecting pumps, valves and hydraulic motors, extending service intervals and lowering operating costs.
Message us for datasheet and performance curve. Let’s deliver robust cooling solutions for Australia’s construction and mining machinery.
#ConstructionMachinery #HydraulicCooling #HeatExchanger #AustralianMining #MobileHydraulics
Whatsapp:+86 15603820837
[email protected]
[email protected]
96
Compound Heat Exchanger for 120 kW Excavator (Texas, USA)
This three-in-one plate-fin compound heat exchanger is designed for a 120 kW medium-duty excavator, serving earthmoving and sand & gravel sites in Texas, USA. Optimized for high ambient temperature and heavy dust conditions locally, it integrates the engine water cooling circuit, charge air cooling circuit and hydraulic oil cooling circuit. It replaces separate radiator, charge air cooler and hydraulic oil cooler, featuring compact layout and strong vibration resistance, complying with North American off-road emission and cooling standards.
The core is vacuum-brazed with 3003 aluminum alloy, dimensioned at 920×660×110 mm. Total heat dissipation capacity reaches 135 kW, including 78 kW for water cooling, 27 kW for charge air cooling and 30 kW for hydraulic oil cooling. Designed ambient temperature: 48°C. Working pressure of water circuit: 0.25–0.35 MPa; maximum pressure of hydraulic oil side: 2.0 MPa; charge air inlet pressure: 0.22 MPa. Rated hydraulic oil flow: 160 L/min; coolant flow: 95 L/min; charge air mass flow: 0.28 kg/s. Maximum continuous operating temperature: 115°C. Serrated offset fins with built-in self-cleaning guides are adopted to mitigate clogging caused by construction dust in Texas.
Matched with a 24V electronically controlled variable-speed fan, it adjusts speed independently based on three-channel temperature signals to cut idle power consumption. Compared with split cooling packages, it achieves around 22% weight reduction and 6 fewer pipe joints to lower leakage risks. Validated by vibration fatigue and pressure cycle tests, it withstands continuous shock and bumping on job sites. It stabilizes engine coolant temperature, intake air temperature and hydraulic oil temperature under heavy loads in Texas summers, prevents thermal derating, and extends service life of hydraulic seals and engine maintenance intervals.
Whatsapp:+86 15603820837
[email protected]
[email protected]
52
Composite Heat Exchanger for 150kW Tractor for Kazakhstan
This composite plate-fin heat exchanger is developed for 150kW agricultural tractors operating in Kazakhstan. It integrates three cooling circuits: engine water cooling, charge air cooling and hydraulic oil cooling. Designed for the local temperate continental climate, it withstands extreme conditions including summer temperatures up to 42°C, winter lows of -35°C and heavy wind-blown dust, meeting heavy-duty continuous farming requirements for large wheat fields. The core adopts vacuum-brazed all-aluminum construction with anti-clogging, dust-resistant fin geometry and salt-spray passivation surface treatment for good resistance to sand and dust corrosion during long-term field operation.
Key parameters: Rated power 150kW, total heat dissipation 135kW; core dimension 720×580×95mm; design working pressure 1.2MPa, test pressure 1.8MPa; coolant: ethylene glycol antifreeze, flow rate 75L/min; charge air inlet temperature 160°C, outlet temperature ≤55°C; hydraulic oil flow rate 42L/min, oil temperature controlled ≤92°C. Slit offset fins are adopted with enlarged flow clearance to reduce dust accumulation. A 24V electric suction fan with temperature-controlled on-off function is equipped.
Balancing heat dissipation and low-temperature thermal retention, the unit delivers stable thermal performance under large temperature differences, preventing overheating risks during cold start in winter and thermal alarms under continuous ploughing in summer. The integrated modular design saves installation space and reduces potential leakage points. It matches local agricultural machinery maintenance practices, suitable for year-round heavy-load operations such as land reclamation, sowing and harvesting in Kazakhstan, and complies with Central Asia export reliability standards.
Whatsapp:+86 15603820837
[email protected]
[email protected]
67
Technical Specification of Lubricating Oil Cooler for 37kW Compressed Air Station, Indonesia
This cooler is matched with the 37kW screw compressed air station for Indonesia project. It adopts brazed plate-fin aluminum structure, designed for the hot and humid tropical working conditions in Indonesia with a maximum ambient temperature of 40℃. It features salt spray resistance to meet the long-term continuous operation requirements of local industrial air stations.
Heat duty: 37kW. Working medium: 46# screw compressor oil. Oil side flow rate: 140 L/min. Design working pressure: 1.6 MPa. Hydrostatic test pressure: 2.4 MPa. Oil inlet temperature: 85℃, target oil outlet temperature: 72℃. Oil side pressure drop ≤0.15 MPa. Cooling type: forced air cooling. Design air inlet temperature: 40℃, air flow rate: 3400 m³/h. Matched fan: 380V/50Hz.
Main material: 3003 aluminum alloy for heat exchange core, vacuum brazed, passivated for anti-corrosion, corrosion class C3, suitable for humid coastal environment of Indonesia. Oil port: G1½, flange connection optional. Overall dimension: 810×460×130 mm, net weight: 36 kg. Temperature sensor port reserved for connection to air station PLC system; alarm signal triggered when oil temperature exceeds 90℃.
Every unit is 100% air leak tested before delivery. Compact structure and easy maintenance. Resists tropical dust and humid air, stabilizes lube oil temperature to avoid compressor high-temperature shutdown and ensures stable compressed air supply for round-the-clock operation of Indonesian factories.
Whatsapp:+86 15603820837
[email protected]
[email protected]
84
Mine Oil Cooler for Chile Mining Operations | Equipped with Explosion-proof 380V AC Motor & Explosion-proof Fan Blades
Chile’s copper and gold mines feature harsh geological conditions. Underground areas contain combustible dust and hazardous gases, imposing strict explosion-proof requirements on the cooling systems of hydraulic and mining equipment. Our custom mine oil coolers are fitted with **380V explosion-proof AC motors and anti-static explosion-proof fan blades**, tailored for high-risk underground mining environments in Chile, to maintain stable oil temperature for heavy-duty excavation and hydraulic systems.
The whole unit complies with mining explosion-proof standards. The flameproof enclosure of the explosion-proof motor contains internal electric sparks to prevent ignition of hazardous underground substances. Matched anti-static explosion-proof fan blades generate no dangerous sparks during high-speed rotation, building dual safety protection from power and air circuit. The plate-fin heat exchanger core resists dust and vibration, adapting to high altitude, heavy dust and large day-night temperature variations in mines. It delivers consistent heat dissipation, controls hydraulic oil temperature, prevents seal deterioration and equipment shutdown caused by overheating, and extends service life of main machinery.
Compact structure enables easy underground hoisting and on-site installation with simple maintenance, greatly cutting mine downtime losses. This complete cooling solution has been deployed in multiple Chilean mining projects, balancing safety compliance and stable production. We focus on thermal management for global mining industries, delivering reliable explosion-proof cooling equipment to support safe and efficient mining operations in Chile.
Whatsapp:+86 15603820837
[email protected]
[email protected]
80
4000CFM Air Compressor Heat Exchanger for Canadian Market
This 4000CFM air compressor heat exchanger is engineered to suit Canada’s variable climate, covering cold winter low-temperature startup and summer high ambient temperature operation. Widely deployed in mining, oil & gas, heavy industry and large manufacturing plants across Canada, it serves stationary large screw and centrifugal air compressors. The robust structure features high pressure resistance, freeze protection and strict material compliance to meet Canadian industrial codes.
Key technical parameters: Air flow capacity 4000CFM (113.3 m³/min). Design working pressure 16 bar (232 PSI). Compressed air inlet temperature up to 190°C. At maximum ambient temperature of 35°C, cooled air outlet temperature ≤48°C. Adopt plate-fin heat exchanger core with aluminum alloy material. The unit is equipped with reinforced baffles and optimized fin structure for high heat transfer efficiency. Connection flange conforms to ASME B16.5 standard. It is fitted with large-capacity condensate drain ports and anti-freeze drain configuration to avoid internal cracking during Canada’s freezing winters.
The heat exchanger undergoes strict pressure and leak testing. Material and welding requirements comply with Canadian local safety specifications. Anti-corrosion coating is applied to withstand dust and moisture in northern mining sites. Modular design simplifies maintenance and spare parts replacement for local service teams. It effectively removes condensate from compressed air, preventing rust and damage to downstream dryers, filters and pneumatic machinery. Stable heat exchange performance reduces unplanned shutdowns and cuts lifecycle operating costs for end users. Suitable for Canadian distributors and EPC contractors for large air compression system projects.
Whatsapp:+86 15603820837
[email protected]
[email protected]
36
Application of 250CFM Aftercooler System in Australia.
This 250CFM air-cooled aftercooler system is widely deployed for open-pit mining, sandblasting and mobile pneumatic engineering across Australia. Tailored for Australia’s harsh operating conditions featuring high ambient temperature, heavy dust and intense sunlight, it serves as compressed air pre-treatment matched with diesel mobile air compressors.
Key parameters: rated air flow 250CFM (7.08m³/min), maximum working pressure 10 bar, inlet air temperature 140°C, designed pressure drop ≤0.35 bar. It cools compressed air close to ambient temperature with an approach temperature ≤10°C. Equipped with 12V DC cooling fan and built-in air-water separator, 1¼ inch NPT inlet & outlet, the whole unit withstands 10 bar working pressure. The heat exchange core adopts brazed aluminum plate-fin structure, and the housing is coated with weather-resistant anti-corrosion coating to meet Australian C4 corrosion class requirements.
Summer ambient temperature in Australian mining sites can exceed 40°C, and massive dust tends to accumulate on cooling fins. The system features enhanced dust-proof construction to support 24/7 continuous operation. Hot compressed air flows into the aftercooler for heat exchange, where most liquid moisture is separated out. This reduces the load of downstream dryers and protects pneumatic tools and sandblasting equipment from pipeline corrosion.
The skid-mounted design enables easy relocation on site, fitted with manual drain valve for simple maintenance. Deployed in mining projects of Western Australia and Queensland, the system reliably cuts moisture content of compressed air and reduces unplanned downtime of downstream equipment. Compliant with local Australian equipment safety standards, it acts as an indispensable thermal management unit for mobile compressed air systems, improving pneumatic operation stability and lowering maintenance costs.
Whatsapp:+86 15603820837
[email protected]
[email protected]
1
1
79
Australia Market|3-in-1 Heat Exchanger Solution for 5m³/min Air Compressor Post Freeze Dryer
Designed for mining, manufacturing and infrastructure working conditions in Australia, this 3-in-1 plate-fin heat exchanger for refrigerated air dryers integrates a pre-cooler, evaporator and air-water separator in one unit. It replaces the traditional split configuration, greatly reducing equipment footprint and on-site installation space, perfectly matching the pain points of compact plant layout and high ambient temperature in Australian sites.
📌 Key Technical Specifications
Rated air handling capacity: 5 Nm³/min; Rated working pressure: 0.7 MPa, pressure range: 0.6–1.6 MPa; Outlet pressure dew point: 2–8°C; Total pressure drop ≤0.015 MPa; Max inlet air temperature ≤45°C; Ambient temperature range: 2–40°C; Refrigerant: R134a; Compatible with Australian 415V/3Ph/50Hz power supply; Brazed aluminum plate-fin construction, salt spray corrosion resistant for harsh Australian indoor & outdoor plant environments.
The integrated heat exchange structure recovers cooling capacity by using cold dry air after drying to pre-cool hot incoming air, cutting refrigeration load with outstanding energy-saving performance. Built-in high-efficiency air-water separation module rapidly removes condensed water, preventing liquid water from entering downstream pipelines and protecting pneumatic equipment.
Compared with conventional separate three-piece assemblies, fewer piping connections drastically reduce potential leak points. Simple maintenance suits remote Australian sites with limited service support.
Compact design for easy on-site commissioning, delivering stable high-quality compressed air. Widely matched with screw air compressors for Australian factories, mines and construction machinery air supply. Australian local distributors and end factories are welcome to inquire about prototypes and custom engineering solutions.
Whatsapp:+86 15603820837
[email protected]
[email protected]
106
# Hydraulic Motor Driven Cooler for US Domestic Hydraulic System Customers
This hydraulic motor-driven air-cooled cooler is custom-designed for US industrial hydraulic customers, applied to mobile hydraulic equipment operating outdoors, and compliant with OSHA safety and installation standards for the North American market. The cooler adopts a plate-fin aluminum heat exchanger core, directly driven by a hydraulic motor for fan operation, requiring no external power supply and suitable for field sites without mains electricity.
Key technical parameters: Rated system flow 60 GPM, maximum working pressure 300 PSI, maximum oil inlet temperature 250℉, design ambient temperature range -20℉ ~ 104℉. The heat dissipation capacity reaches 28kW under an oil temperature difference of 30℃. The matched drive hydraulic motor has a displacement of 16cc/r, with operating pressure range of 120–210 bar. Fan speed adjusts automatically with system oil pressure. A built-in temperature-controlled bypass valve protects the system during cold start and prevents high-pressure impact from cold oil. SAE standard ports are adopted for easy on-site piping connection by customers.
The heat exchanger core is manufactured by vacuum brazing, featuring vibration resistance and C4 salt spray protection, adapting to large temperature variations and humid conditions across regions in the US. The complete cooler can withstand continuous shock loads, reduce high-temperature performance degradation of the hydraulic motor, stabilize system oil temperature, and mitigate risks of seal aging and oil oxidation. All units undergo hydrostatic testing and performance verification before delivery. North American technical drawings and test reports are provided, along with on-site installation and commissioning guidance. It matches heat dissipation requirements of construction machinery, mining equipment and other hydraulic systems.
Whatsapp:+86 15603820837
[email protected]
[email protected]
121