Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)Photo by Jay burrows (@Jayburrows5)
Just thought I might update you on the latest ‘best’ energy deal available for a pub of our size. We were paying 15p/unit in May. This is the best quote available today. – at Birkenhead, England
973
4,094
1,471
12,049
Hi guys, anyone who is a PV expert out there could they tell me if the contractor who has fitted my panels have voided my manufacturer warranty because the have screwed into frame to support this netting. Thanks in advance.
What do we reckon on this the bag of 💩 customer paid £2200 for this and a electrical inspection. No building control notice no certificate, 0.20M0 on the ring multiple spurs. Complete mess.
13
6
Don’t but a new boiler online, get a decent local installer to do the job properly – at Manchester, England
Wow. Boxt you should be winning some award with this Mona Lisa of an install. Brazo 👏
3
4
24
Another quality job. Plus a bit of mould for good measure 🤮
2
I'm holding a Zoom call every Sunday at 2pm from now on for anyone looking to enter the electrical trade from school, maybe looking to change career, or maybe you are already in training and need some advice or guidance I have to limit numbers, DM me and I will send you a code
11
18
Quick question. I have a job with a 70 meter run of 16mm armoured fed from a PME Supply, there’s are wet room going in with a plastic poly supply. Copper to the sanitary ware. Because of the distance do I need to TT this now?🤔
What do we reckon of this being used as a dual tariff consumer unit!.
3
4
Another day another EICR. 🥱
1
3
That’s where the 2M0 reading coming from 🙄
1
Technician came and wired the oven. 😂😂 technician.
1
There shit and there shit, this a pile up. 6mm feeding a sub board via 80amp cut out. It’s has also been split before the sub board to supply the kitchen sockets😬 so the wiring in the kitchen has a 80amp overcurrent device. List goes on.
1
1
5
Been in this house 15 minutes. And I’ve decided not even bother testing it. Botched everywhere. What the point. 6mm feeding upstairs loft room via a 80amp cut out fuse. 🤦‍♂️
3
13
This man tried to steal my friend’s dog in Kings Cross yesterday. She got this picture of him. He has also been reported today doing the same thing in Belsize Park. Look out for him in North London dog owners x
319
5,483
252
3,865
State of this, customer had a someone to replace a fan, looks like he’s had a fight with cables, tripping the board out, this duct is completely full of water.🤦‍♂️