fda pulled two more sex supplements this week, a honey with hidden tadalafil and capsules with sildenafil plus acetaminophen nobody listed. lc-ms picks up pde5 drugs pretty easily, someone just has to look for them. This is one of teh basic screens offered at Vanguard
112
Vanguard Laboratory retweeted
3M agrees to $7.35B settlement over PFAS groundwater contamination. 3M has agreed to pay up to $7.35 billion to settle lawsuits over groundwater contamination from potentially harmful chemicals in firefighting foam. ehsciences.emlnk9.com/lt.php…
5
53
3
71
1,319
whole foods 365 ashwagandha capsules recalled for salmonella, lot 2025-26227. dried roots and herb powders are a known source and salmonella can survive for months in a dry powder. Every lot should be tested for microbial contamination.
2
1
4
392
Another cinnamon recall for lead, wise wife brand this time. Lead in spices usually comes from soil, worn grinding equipment, or worst case lead chromate added to brighten color. you cant see or taste any of it, only a lab analysis will detect it. Vanguard routinely tests spices, baby formula, and supplements for heavy metal contamination. Spices and herbal supplements are the worst offenders.
1
1
198
At the Evergreen State College job fair today, table 6. We brought an SRI 8610C GC with purge and trap so students can see what's inside one. If you're into chemistry or micro come talk to us about lab work in Olympia. #EvergreenStateCollege #Olympia #JobFair #Chemistry #Microbiology #GasChromatography #LabJobs #VanguardLaboratory
1
5
362
We appreciate the votes.
Which of these testing labs would you prefer a COA to be from?
38%Vanguard
17%TrustPointe
36%Janoshik
9%Chromate
102 votes • Final results
1
3
1,292
Vanguard Laboratory retweeted
Replying to @PeptideBriefs
Well u need join to find out and then let me know your suggestions t.me/+SDb9toUM7Q4zNDg5
1
10
1,171
Vanguard Laboratory retweeted
K‑Hole has had an update following the latest nuke this morning. There are now two Telegram groups: 🕳️ K‑Hole Shadow 3.2: the replacement community. Invites will be going out shortly. 🔬 K‑Hole Lab Chat: a standalone group for lab questions, COAs, testing and discussions with laboratories. No vendors, sales talk or promotions. Each lab has their own topic. Please respect the group rules and Telegram’s Terms of Service so we can keep Lab Chat alive. My new website is also launching soon.
16
3
1
111
7,948
Vanguard Laboratory retweeted
Beeboo Off the Hook? Plot twist: Vanguard tested ten separate 5-Amino-1MQ samples, including an authenticated reference standard and one believed to be from the affected vendor. At high concentration, they all triggered presumptive positive fentanyl strips. When diluted according to the manufacturer’s instructions, they all tested negative. Targeted LC-MS/MS also returned nondetect across the fentanyl panel. We're still waiting for the national laboratory’s result on Janoshik’s sample, but for now, it looks like Beeboo’s brew may be clear, and Beeboo can sleep at night again. Article link below
2
18
6,555
Vanguard Laboratory retweeted
Why Was Hydroxyacetophenone Added to Zero-Peptide Vials? One theory is that hydroxyacetophenone was deliberately added to make fake raw material produce a reading during basic UV testing. The substance is visible at both 214 and 280 nm. Absorbance around 214 nm is commonly used to detect peptide bonds, while 280 nm mainly reflects tryptophan and tyrosine. If an upstream facility performed only a quick UV-Vis check, the hydroxyacetophenone could produce absorbance and make a mixture of mannitol and no peptide appear as if something peptide-like were present. According to @Vanguard_Lab it would take around a minute, require no specialist solvents and cost next to nothing. This would not fool HPLC or mass spectrometry, and it would not confirm the identity of any peptide. It could only potentially fool someone using a basic UV reading as a shortcut instead of properly analysing the material. That could explain why the vials contained hydroxyacetophenone rather than mannitol alone. The chemical may have been included to help fake raw material pass a cheap upstream quality check before reaching the finisher. It remains a theory. But if correct, the zero-peptide vials were not simply empty, they may have been designed to pass the most basic test.
4
4
38
4,653
Vanguard Laboratory retweeted
Replying to @Vanguard_Lab
@Vanguard_Lab submitted evidence today on the reptides lab board describing their QA process, certificates, and what makes them capable of testing peptides. Based on the information we received, we would like to welcome our first A-tier lab to the reptides board.
3
4
10
672
You sent one vial to the lab. The report came back clean. Does that mean your entire 500-vial shipment is good to go? No. Before you test, you need a sampling plan based on risk assessment. Full article link below. vanguardlaboratory.com/pepti…
1
4
2
16
76,969
Validated methods. Legally defensible data. Independent quality checks. Vanguard participates in proficiency testing for every method where PT is available. For methods without a formal PT program, we conduct interlaboratory round-robin comparisons with other ISO-accredited laboratories. Our latest PT highlights include USP-related pharmaceutical testing and food microbiology detection methods, supporting reliable data for regulated industries.
🤖 Made with AI
1
9
1,293
Another Fraudulent COA, this time they redesigned our logo. If ever in doubt about a COA's authenticity visit verifiedbyvanguard.com, email us , or call(360) 967-7010 and we will happily tell you if it is legitimate.
6
4
2
30
4,696
Important note for clients submitting injectable samples: Microarray and PCR-based screens are not USP <71> sterility tests, and they are not recognized as compendial sterility methods under USP <71>, <72>, or <73>. USP <71>, <72>, and <73> remain the official compendial sterility tests for injectable products. Rapid or molecular methods may have research or screening value, but they should not be represented as USP sterility testing unless they fully meet the applicable USP compendial requirements and validation expectations. Always ask the lab: “Is this a true USP compendial sterility test (<71/72/73>), or a non-compendial rapid method?” Your compliance depends on clear answers. #USP #SterilityTesting #PharmaQC
1
1
1
2
2,406
That “all-natural” herbal pain supplement that works surprisingly well? Sometimes the secret ingredient is not an herb. This overlay shows a product sample matching a diclofenac sodium standard an actual pharmaceutical that was not disclosed on the label. Trust, but verify with chromatography. Vanguard has validated full NSAID test panels for HPLC, and LCMSMS with PPB level detection limits.