Joined March 2018
Well-done demonstration of utilizing #HDGRID and #PDX for a PVC originating from the anterolateral papillary muscle. Successful radiofrequency ablation with #Tacticath #Ensite.
3
26
1,915
Credit to the EP team in Bern for this excellent remapping study after either RF or PFA. Mandated remapping is much better than remapping for symptoms jacc.org/doi/10.1016/j.jacep… A) PFA no better than RF for durable PVI B) Recapitulates GAP study showing that AF still occurs in one-third of durably isolated PVs and 72% of those with reconnected veins DID NOT have AF at one year This is the crux of our problem in EP: we don't understand the pathophysiology of the condition. PVs get isolated because we can. @TobiasReichlin
2
25
1
86
8,367
Great session from Dr. @RolandTilz on early clinical experience with VT and PVC Ablation with a Dual-Energy (RF/PF) Flexible-Tip Ablation Catheter at #VTSymposium. More insights from him on LinkedIn: lnkd.in/gTjsJ5tY #LetsDuoIt
11
23
1,768
Successful LV summit PVC ablation using #TactiflexDuo ⚡️🔥 ​Challenging location, but delivered safe, effective PFA to eliminate the PVC without complications. #LetsDuoIt ⚡️🔥
3
3
29
2,874
Exceptional (literally) case in Canada PF stacking at far field isthmus resulting in VT termination and immediate non inducibility Super support from our hospital and Abbott @JACCJournals jacc.org/doi/10.1016/j.jacca…
In this 3D VT, #EnSiteX and #HDGridX revealed a midmyocardial isthmus. Then, dual-energy delivery with #TactiFlex Duo helped terminate the circuit. Thanks, Dr. @AlexiosHadjis and team, for showing what's possible with our tech. Read in JACC: jacc.org/doi/10.1016/j.jacca… #AbbottProud
13
61
112,581
Redo AFL case, post-PVI/MI/roof line with another PFA. #HDGridX + #EnSiteX found the gaps at the LSPV (going in on the posterior of the LSPV and going out on the anterior) — #TactiFlexDuo closed it and terminated the AFL. #LetsDuoIt ⚡️🔥
1
3
38
3,062
Single catheter workflow with #Volt—map and ablate without changing catheters. #VoltPFA #abbott #RevoltAgainstTheOrdinary
12
60
4,974
ReVolt against the ordinary ⚡️ PVI + PWI + CTI with #Volt PFA
12
62
5,725
Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocol, by @PerWenzel and colleagues @UKSH_KI_HL @dzhk_germany #EPeeps heartrhythmopen.com/article/…
15
45
3,435
nami retweeted
🚨New #OpenAccess Article in @JICE_EP Safety & Performance of the Novel Balloon-in-Basket PFA System: Initial 100-Patient Experience at a High-Volume Electrophysiology Center 🧐📖doi.org/10.1007/s10840-026-0… by @RolandTilz, Sascha Hatahet, @CharlotteEitel, Sorin Popescu, Roman Mamaev, Kohei Ukita, Mirco Küchler, @Suzanne_de_Waha, Karl-Heinz Kuck & @PerWenzel #EPeeps
9
1
23
3,958
Atypical Atrial Flutter congenital heart post surgery & prior PFA Mapped with #EnSiteX + #HDGridX + #TactiFlexDuo Seamlessly switching between RF and PFA allows us to tailor the lesion directly to the specific scarred & tissue thickness we encounter ⚡️🔥 ​where would you burn?
1
7
1
39
4,632
🎉 Excited to share highlights from one of our very first cases with Tactiflex Duo for PVI 🌟First-pass PV isolation done safely, and in a similar pocedure time to single short PFA. #LetsDuoit #Abbott #TactiflxDuo #HDgridX #EnsiteX
1
15
64
5,099
nami retweeted
🚨Latest #OpenAccess Article in @JICE_EP Lattice-Tip Dual Energy Ablation Creates Effective Ventricular Lesions through Transmural Scar that Might Inadvertently Increase Lead Capture Thresholds on the Opposing Surface 🧐📖doi.org/10.1007/s10840-026-0… by @vish_luther, Laura Brodie, @justinchiong, Peter Calvert, Daniel Walker, @DhirajGuptaBHRS & Nathan Denham #EPeeps
10
1
24
3,606
Dual-modality (PF +/- RF) ablation shows promise for refractory LV summit PVCs—100% acute success, durable outcomes, and manageable safety profile @akillumd @noseworthypeter @EzzeddineMD @nicktanCV @DrDeese99 #Epeeps #PFA ahajrnls.org/4mZCEcT
2
38
1
78
8,353
Intramural anteroseptal substrate, incessant VT with exit close to His region, inducible after RCC 3 RF apps (50W, 90sec each), effective and safe PFA with Tactiflex Duo in RCC with low dose to avoid His damage and coronary spasm @PranavBhagirath @hospitalclinic @aportasanchez
5
30
121
4,866
Ventricular fibrillation can occur immediately after pulsed field energy delivery — even without R-on-T or reproducibility. A rare but important reminder as PFA expands beyond PVI. 👉 Vigilance is key during posterior wall ablation @CardiologyTokai #PFA #AFablation #EPeeps
Ventricular Fibrillation Immediately Following Pulsed Field Energy Delivery in Persistent Atrial Fibrillation @AtsuhikoYagish1 heartrhythmcasereports.com/a…
2
11
52
8,003
Got an interesting Bi-Atrial AFL case today ! Where would you burn ?
3
8
62
5,550
Kerfed Tip Enhances Catheter Stability During Accessory Pathways Ablation in Children heartrhythmjournal.com/artic…
4
24
2,713
Posterior mitral isthmus ablation using a balloon-in-basket pulsed-field multielectrode catheter heartrhythmcasereports.com/a…
10
1
36
4,273