Ilie T. Barb (@ibarb_) header
Ilie T. Barb (@ibarb_) profile picture

Tweets mine/ not medical advice; RT not endorsement. #passionmatters

Gainesville, FL
Joined January 2014
Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)Photo by Ilie T. Barb (@ibarb_)
More #TAVR #TAVI #ViV 19 mm Mitraflow... with double coronary protection guide/guideliner/ balloon .. coronary clearance better. Mitraflow unpredictable at best... Best degenerated #mitraflow is the one surgical excised straight into the “garbage can” of history
3
7
1
25
Had a few cases where I needed to remove the GEC without pulling out the balloon or stent catheter. Always thought a peel-away option would be great. Today, I improvised one. Should manufacturers provide a dedicated slitter tool, or is this too niche a problem? #CHIP #PCI
4
6
26
14,387
Ilie T. Barb retweeted
#Ostial Protection #WALPO Technique “The aortic free-floating wire technique, Aorta for Localization and Protection of the Ostium provides a method for safely locating and protecting the ostium during PCI, ⬆️ safety and efficacy of PCI at this location.” bit.ly/3ZcvG96
6
48
3
218
25,831
Read 🔟 key points from a state-of-the-art review on multimodality imaging in the diagnostic work-up of patients with cardiac masses. 🔗 bit.ly/3YP5TTY @JACCJournals #JACCCardioOnc #CardioOnc
83
6
193
32,300
Microcatheter and IVL: a winning combination? @Franchina_AG @MrcTsl
2
17
73
8,768
Failed to withdraw the device into the sheath despite multiple attempts. The 30 mm device could not be withdrawn into 14 F sheath despite manipulations. What could be the reason? Options?
31
30
1
121
48,324
Today is the 47th anniversary of the 1st coronary angioplasty, performed in 1977 in Zurich by Andreas Gruentzig. Here is our story, told by the 1st patient himself, Adolph Bachman, and his doctor, Bernhard Meier. #AngioHistory
1
74
1
156
14,307
at normal loading condition, shift to radial/circumferential contraction with volume and more so pressure overload
75% of right ventricular systolic function depends on longitudinal function
1
6
1
28
3,299
There is a good article in Indian Heart Journal about the subject. @latchumanadhas
1
9
51
5,383
The moment you realize you found a new work family. Thank you Ascension Cardiology! I am falling in love with Wisconsin fast!
1
4
373
To my Cardiology people: I need you help. Please share if you think it’s appropriate. I am looking for several non-invasive and interventional cardiologists to help me grow our Ascension program in and around Milwaukee.  - Vibrant, multicultural downtown with things to do - Safe, quiet suburbs with excellent schools - Team of experienced Cardiologists who treat each other as family members - Prioritize work/life balance - Competitive compensation - Generous vacation - Fellows are encouraged to apply - Will consider part time  - Will help with H1B sponsorship and J1 visa waiver If you would like to learn more, or of you know a colleague who might be interested, please reach out to me directly via email [email protected] or by phone at 414-298-7165. Or just PM me
13
2
21
3,642
Ilie T. Barb retweeted
Finally!!! excited to have this available to us in the US! @BSCCardiology
We are excited to announce AGENT™ Drug-Coated Balloon is now FDA approved! AGENT is the first and only coronary drug-coated balloon in the U.S. and introduces a new treatment option for patients with in-stent restenosis. bit.ly/3wuLYiM
3
7
1
68
9,482
Ilie T. Barb retweeted
A great resource for LAMPOON- a step by step guide easily accessible for supply list and procedural steps! #CardioTwitter Want to see the full case and guide from @TheNarulaSeries?
1
7
17
4,103
The #EAPCI community mourns the sudden loss of Alain Cribier, a pioneering #IC known for numerous 'firsts' including the first-in-man #TAVI on April 16, 2002. Our heartfelt condolences to his family, friends + colleagues. His wisdom, expertise and guidance will be greatly missed.
46
244
61
515
192,688
I never used a Wiktor, but this image makes me think it might be one (C=Wiktor; F =AVE). The AVE stent had multiple welds connecting each ring, and was thicker than most stents back then. This one seems to have only one weld per ring and to have fairly thin struts.
3
3
14
1,004
Great technique Tipp for complex Coronary procedures by @JEscaned at #CTOCHIPMeeting in Hamburg Reverse trapping Ballon Technique to advance Stents in calcified lesions and tortuous vessels. @HolgerNef @stefan_harb @KambisMashayek1 @KardiologieHH @Obisht
3
7
32
3,955
Ilie T. Barb retweeted
#STEMI in post-TAVR patient w/ #CorValve Evolut PRO+ 😬 Coronaries usually accessed through side struts of this #TAVR valve (see ref below) ➡️ But in this case, enough room to go around valve (29 mm valve, 39 mm root, 44 mm ascending aorta) ncbi.nlm.nih.gov/pmc/article…
1
8
1
50
3,468
Mechanism of SCAD - we propose “Acute Mechano-cardiac Coronary Artery Disruption”. Not so spontaneous? #AMCAD #SCAD @marysia_tweet @DevikaKir @adnanalkhouli @KUEVC_Simari @SVRaoMD @SharonneHayes @mmamas1973 @djc795 @mandeep_mayo @Hragy
Dr. @rajivxgulati, et al offer a collection of observations that support an alternate hypothesis in many cases—that #SCAD is a secondary event instigated by SICM (Takotsubo and variants). Learn more here: bit.ly/3O9yYoQ #JACCAdvances #cvCAD
10
63
10
171
51,732