Replying to @peterramsing @willking
*move it back in the wall cavity if you need the sheet rock to cover
11
Replying to @willking
And you'll want those back in the junction box. Code or no code, let those wire nuts be in the metal box, not loose in your wall (but code says they must be in the box*).
*not licensed electrician, everything I say will and is being used against me
move it back in the cavity
1
28
*to be clear: you're awesome to do this yourself! thank you for doing it yourself. Please do more things like this yourself! DO IT!
2
23
Replying to @EmmettNaughton @willking
1. did you pull each wire hard while holding the wire nut (4 tugs, one per wire) - nothing should budge
2. once verified they are snug, tape the wirenut, too.
1
1
18
Replying to @peterramsing @willking
or I could get really controversial and say use WAGOs. I prefer them to wire nuts especially if you're not super experienced using wire nuts.
...but wire nuts are great, too. Just be sure to pull each lead hard after tightening to make sure you've got them both.
1
14
Replying to @WarrenInTheBuff @willking
+1 for making sure the breaker is off.
...but you can totally do this. No need for electrician! You got this!
1
18
Replying to @peterramsing @willking
*this is not correct advice per code... you'd at least want to secure it further back... but I can't think of any reason why it'd be dangerous. The only risk is future remodels?
1
6
Replying to @willking
OR... you could just pull the box of the stud, put kid-safe plug covers on, and leave the whole thing abandoned in the wall?
1
9
Replying to @willking
e.g. Pending if there's actually going to be current passing through vs just being completely dead. But you want a strong connection or you get heat... heat is no good.
2
Replying to @willking
you mean electrical tape? I wouldn't just use tape. You want a mechanical bond.
I'm not an electrician but I've done a tonne of work with electrical... DM and I'd be happy to facetime
10
Replying to @SachinRamje @dickiebush
Oi... I do need a walk.
<bing>
Hold on, Claude just finished a loop - must keep it running.
1
10
is it just me or is Opus 5.5 very into telling you how much something is going to cost today?
1
1
73