One of 4 regular IP65 downlights fitted in a soffit all have failed. Currently integral units. Replace all with another integral version or a can with GU10. In the future the lamp is easier to change but perhaps more often? Thoughts?
3
2
417
So, you can join copper to aluminium to make it look good but a half decent insulation tester will out you fast.
Aluminium socket wiring, never seen so many testing failures in such a short time. Rewire needed. Whoever thought this was even a good idea
1
3
224
Great info condensed in the same place
Read Peter's, our RM for the South, insightful blog, "Navigating Standards, Regulations and Legislation" which provides a clear overview of the relevant BSI Standards, Building Regulations, and Legislation.
Check it out here👇
lnkd.in/eZDc9Vnc
2
250
Water heated solar controls. Any advice? Working on a house which has solar water heating. This circulates when the solar temp is higher than the immersion tank, or should. The water temp is really high and the controller is dated with no manual. Ideally a replacement needed.
1
215
On holiday in Corfu. Only one thing is distracting me from this glorious view from the balcony. I just need a ladder and 15 minutes, done! 😎🤭
2
12
582
Interesting (long long) thread. It does make you wonder how things could change on Thursday.
Two futures:
Labour in Government. Tories in Opposition. 5 years of endless culture wars & immigrant-bashing.
Labour in Government, LibDems in Opposition. Tories powerless & voiceless on back benches.
If the Tories come third, it changes everything. Here's why:
1/12
1
211
I can’t make the installer show but if you’re going check out Tepeo - and their zeb
@InstallerSHOW can we get a re-share please for @tepeoPRO 👌🎟️
2
269
Pulling my hair out trying to set the dimmer for a v-pro, done it many times… then I remembered it was a Knightsbridge… duh!
1
3
194
May I please get 2 followers to copy and paste this tweet? I'm trying to demonstrate that someone is always listening 💯 #SuicidePrevention
0800 689 5652
Just two.
Any two.
Copy not retweet
Just added a comment to the amendment 3 DPC. I don’t like the new term ‘power flow’ (albeit probably correct in this concept).
I can be a bit dim and generally need someone sensible like @jwflame to better (and simply) explain it rather than the IET.
4
2
711
So, thermostat not working…. I can now see why and also realise I need to sort all this shit out. Kitchen fitters! What a shit job.
1
8
335
Main switch RCD. Nuisance tripping caused by combined leakage. Could the RCD get close to tripping but a DC element saturates the coil and stops it. When DC leakage devices are turned off, saturation stops and RCD trips. So trips when turned something off not on. Sound plausible? – at Uckfield, England
7
6
971